Station Information
Location:
Coordinates:
Elevation:
Site Description Station History

Station Name

  • Site Installed: 04/24/09
Location
Coordinates
Elevation
Time Recording Standard Alaska Standard Time (UTC-9)
Sensor Details
SCSM2
  • Images: CC640 Digital Camera (1)
    • Memory Capacity : 1G Flash Memory Card (30,000 image capacity)
    • Image Trigger Interval : 30-minutes
    • Image Retrieval Interval : One every hour

  • Wind Speed: RM Young 05103 Marine Anemometers (2)
    • Accuracy: 60.6 mph
    • Operating Range: 0 to 60 m/s (0 to 134 mph)
    • Starting Threshold: 1 m/s (2.2 mph).
    • Height: 30 feet
    • Output Units: meters per second
    • Scan Interval: 5 seconds

  • Wind Direction: RM Young 05103 Marine Anemometers (2)
    • Operating Range: 0 to 360 deg (mechanical) True North (0 to 355 electrical, 5 deg open)
    • Starting Threshold: 1.1 m/s (2.2 mph) 10 deg displacement
    • Installation: Align true north
    • Height: 3 meters
    • Output Units: degrees true north
    • Scan Interval: 5 seconds

  • Air Temperature: HPM45C Vaisala AT/RH sensor
    • Operating Range: -40°C to +60°C
    • Installation: In 12-gill radiation shield, non-aspirated
    • Height: 2 meters (6.6 feet)
    • Output Units: °C
    • Scan Interval: 60 seconds

  • Air Temperature - Cold Range: Triplicate YSI Series 44033 thermistors
    • Operating Range: -80°C to +75°CC
    • Installation: In 6-gill radiation shield, non-aspirated
    • Height: 2 meters (6.6 feet)
    • Output Units: kW, °C.
    • Scan Interval: 60 seconds

  • Relative Humidity : HPM45C Vaisala AT/RH sensor
    • Operating Range: 0 to 100% RH
    • Installation: In 12-gill radiation shield, non-aspirated
    • Height: 2 meters (6.6 feet)
    • Units: % Relative Humidity
    • Scan Interval: 60 seconds

  • Dew Point Temperature : Calculated value from AT/RH
    • Scan Interval: N/A, calculated

  • Wind Chill Temperature : Calculated value from Air Temperature and Wind
    • Scan Interval: N/A, calculated

  • Barometric Pressure : CS106 (Vaisala) at West station only
    • Installation: inside the datalogger enclosure
    • Height: about 1.5 m
    • Output Units: hPa (mb)
    • Scan Interval: Hourly

  • Snow Depth: Campbell Scientific SR50a Sonic Ranging Sensor
    • Operating Range: 0.5 to 10 meters (or sensor height, if less than 10 m)
    • Resolution: 0.25 mm
    • Installation: Point straight down on a flat surface
    • Height: 2 meters (6.6 feet)
    • Output Units: cm, corrected for air temperature
    • Scan Interval: 60 seconds

  • Surface Soil Temperature : Triplicate YSI Series 44033 thermistors
    • Depths: 1cm (surface), 3 thermistors
    • Output Units: kW, °C
    • Scan Interval: Hourly

  • Tower Maintenance Soil Temperature: Triplicate YSI Series 44033 thermistors
    • Depths: 30cm (1 ft), 3 thermistors
    • Output Units: kW, °C
    • Scan Interval: Hourly

  • Soil Temperature Profile: YSI Series 44033 thermistors (12)
    • Installation: In back-filled bored hole
    • Depths: 0, 5, 10, 15, 20, 30, 40, 60, 80, 100, 120, 150 cm, 1-12 thermistors (based on actual depth of bored drill hole)
    • Output Units: kW, °C
    • Scan Interval: Hourly

  • Summer Precipitation: TE525WS
    • Resolution: 0.01 in (0.25mm)
    • Installation: use wind shield, locate 30 m from nearest obstruction
    • Height: 0.5 meters
    • Output Units: mm
    • Scan Interval: 60 seconds

  • CR1000 Battery Voltage: CR1000
    • Output Units: V
    • Scan Interval: 60 seconds

  • CR1000 Solar Panel Voltage: GWS Wiring Harness, CR1000
    • Output Units: V
    • Scan Interval: 60 seconds

  • Battery Bank Temperature: YSI Series 44033 Thermistor
    • Output Units: kW, °C
    • Scan Interval: 60 seconds

  • Datalogger (CR1000) Panel Temperature: CR1000 Internal thermistor
    • Output Units: °C
    • Scan Interval: 60 seconds