Station Information
Location:
Coordinates:
Elevation:
Site Description |
Station History |
Station Name |
|
- Site Installed: 06/15/04
- Telemetry Established: 09/15/07
|
Location |
|
Coordinates |
|
Elevation |
|
Time Recording Standard |
Alaska Standard Time (UTC-9) |
Sensor Details |
- Data Acquisition: CR1000-XT Datalogger
- Memory : 4 Meg
- Extended Temperature Range : -55C to 85C
- Functions : Data acquisition and control, high-quality measurements, flexibility for all required data standards
- Telemetry : RF450 Spread Spectrum Radio
- Images: CC640
Digital Cameras (3)
- Image Trigger Interval : 60 minutes
- Image Retrieval Interval : 60 minutes
- During low light conditions (night/winter months) photos are black
- Wind Speed: RM
Young 05103
Anemometer
- Accuracy: 60.6 mph
- Operating Range: 0 to 60 m/s (0 to 134 mph)
- Starting Threshold: 1 m/s (2.2 mph).
- Height: 3 meters (10 feet)
- Output Units: meters per second
- Scan Interval: 5 seconds
- Wind Direction: RM
Young 05103
Anemometer
- Operating Range: 0 to 360 deg (mechanical) True North (0 to 355 electrical, 5 deg open)
- Starting Threshold: 1.1 m/s (2.2 mph) 10 deg displacement
- Installation: Align true north
- Height: 3 meters (10 feet)
- Output Units: degrees true north
- Scan Interval: 5 seconds
- Air Temperature - Cold Range: GWS triplicate sensor incorporating the 44033RC Precision Epoxy NTC thermistor
- Operating Range: -55°C to +105°C
- Installation: In 6 plate Gill Radiation Shield, non-aspirated
- Height: 2 meters (6.6 feet)
- Output Units: °C.
- Scan Interval: 1 minute
- Wind Chill Temperature : Calculated value from Air Temperature and Wind
- Scan Interval: N/A, calculated
- Barometric Pressure : CS106 (Vaisala)
- Installation: inside the datalogger enclosure
- Height: about 1.5 m
- Output Units: hPa (mb)
- Scan Interval: Hourly
- Snow Depth: Campbell
Scientific SR50a Sonic Ranging Sensor
- Operating Range: 0.5 to 10 meters (or sensor height, if less than 10 m)
- Resolution: 0.25 mm
- Installation: Point straight down on a flat surface
- Height: 2 meters (6.6 feet)
- Output Units: cm, corrected for air temperature
- Scan Interval: 60 seconds
- Surface Soil Temperature : Triplicate YSI Series 44033 thermistors
- Depths: 1cm (surface), 3 thermistors
- Output Units: kW, °C
- Scan Interval: Hourly
- Summer Precipitation: TE525WS
- Resolution: 0.01 in (0.25mm)
- Installation: use wind shield, locate 30 m from nearest obstruction
- Height: 0.5 meters
- Output Units: mm
- Scan Interval: 60 seconds
- Winter Precipitation: NOAA Weighing Precipitation Gauge
- Resolution: 0.01 in (0.25mm)
- Installation: use wind shield, locate 30 m from nearest obstruction
- Height: 2 meter (6 feet)
- Output Units: in
- Scan Interval: 60 seconds
- Pressure Transducer: CS450 Sensors (2)
- Operating Range: 0 - 2.9 psig
- Installation: Bottom of streambed
- Standard Accuracy: ±0.1% FS TEB
- Compensation Temperature: 0°C to 60°C
- Output Units: psig
- Scan Interval: 1 minute
- Water Temperature: CS450 Sensors (2)
- Operating Range: -10°C - +80°C
- Installation: Bottom of streambed
- Output Units: °C
- Scan Interval: 1 minute
|