- Images: CC640
Digital Camera (1)
- Memory Capacity : 1G Flash Memory Card (30,000 image capacity)
- Image Trigger Interval : 30-minutes
- Image Retrieval Interval : One every hour
- Wind Speed: RM
Young 05103
Marine Anemometers (2)
- Accuracy: 60.6 mph
- Operating Range: 0 to 60 m/s (0 to 134 mph)
- Starting Threshold: 1 m/s (2.2 mph).
- Height: 30 feet
- Output Units: meters per second
- Scan Interval: 5 seconds
- Wind Direction: RM
Young 05103
Marine Anemometers (2)
- Operating Range: 0 to 360 deg (mechanical) True North (0 to 355 electrical, 5 deg open)
- Starting Threshold: 1.1 m/s (2.2 mph) 10 deg displacement
- Installation: Align true north
- Height: 3 meters
- Output Units: degrees true north
- Scan Interval: 5 seconds
- Air Temperature: HPM45C Vaisala AT/RH sensor
- Operating Range: -40°C to +60°C
- Installation: In 12-gill radiation shield, non-aspirated
- Height: 2 meters (6.6 feet)
- Output Units: °C
- Scan Interval: 60 seconds
- Air Temperature - Cold Range: Triplicate YSI Series 44033 thermistors
- Operating Range: -80°C to +75°CC
- Installation: In 6-gill radiation shield, non-aspirated
- Height: 2 meters (6.6 feet)
- Output Units: kW, °C.
- Scan Interval: 60 seconds
- Relative Humidity : HPM45C Vaisala AT/RH sensor
- Operating Range: 0 to 100% RH
- Installation: In 12-gill radiation shield, non-aspirated
- Height: 2 meters (6.6 feet)
- Units: % Relative Humidity
- Scan Interval: 60 seconds
- Dew Point Temperature : Calculated value from AT/RH
- Scan Interval: N/A, calculated
- Wind Chill Temperature : Calculated value from Air Temperature and Wind
- Scan Interval: N/A, calculated
- Barometric Pressure : CS106 (Vaisala) at West station only
- Installation: inside the datalogger enclosure
- Height: about 1.5 m
- Output Units: hPa (mb)
- Scan Interval: Hourly
- Snow Depth: Campbell
Scientific SR50a Sonic Ranging Sensor
- Operating Range: 0.5 to 10 meters (or sensor height, if less than 10 m)
- Resolution: 0.25 mm
- Installation: Point straight down on a flat surface
- Height: 2 meters (6.6 feet)
- Output Units: cm, corrected for air temperature
- Scan Interval: 60 seconds
- Surface Soil Temperature : Triplicate YSI Series 44033 thermistors
- Depths: 1cm (surface), 3 thermistors
- Output Units: kW, °C
- Scan Interval: Hourly
- Tower Maintenance Soil Temperature: Triplicate YSI Series 44033 thermistors
- Depths: 30cm (1 ft), 3 thermistors
- Output Units: kW, °C
- Scan Interval: Hourly
- Soil Temperature Profile: YSI Series 44033 thermistors (12)
- Installation: In back-filled bored hole
- Depths: 0, 5, 10, 15, 20, 30, 40, 60, 80, 100, 120, 150 cm, 1-12 thermistors (based on actual depth of bored drill hole)
- Output Units: kW, °C
- Scan Interval: Hourly
- Summer Precipitation: TE525WS
- Resolution: 0.01 in (0.25mm)
- Installation: use wind shield, locate 30 m from nearest obstruction
- Height: 0.5 meters
- Output Units: mm
- Scan Interval: 60 seconds
- CR1000 Battery Voltage: CR1000
- Output Units: V
- Scan Interval: 60 seconds
- CR1000 Solar Panel Voltage: GWS Wiring Harness, CR1000
- Output Units: V
- Scan Interval: 60 seconds
- Battery Bank Temperature: YSI Series 44033 Thermistor
- Output Units: kW, °C
- Scan Interval: 60 seconds
- Datalogger (CR1000) Panel Temperature: CR1000 Internal thermistor
- Output Units: °C
- Scan Interval: 60 seconds
|